UTILITIES INLET

ELECTRIC POWER

Full plant (kw) Intergrade plant (kw)
Bitumen Storage and off-load 100 80
Compounding Equipment xMix 106 750 375
Filler Storage 25 20
Thermal Circuit 150 100
Air Compressor 54 32
Sand Distribution 12 12
Water Cooling and Circulation 28 17
Production Line 260 130
Pallet Packaging 35 19
total installed 1414 785
total absorbed 650 360

DIATHERMIC OIL

DIATHERMIC OIL to fill up the thermal plant. The total amount depends of the length of the piping but approximately we can talk about 42000 liters (23000)

NATURAL GAS or METHANE

NATURAL GAS or METHANE are used in three different point:

Full plant (N m³) Intergrade plant (N m³) Pressure (mbar)
Thermal Unit for diathermic oil 650 325 100
Production Line 72 36 20
Thermoshrinkable Unit 46 23 20

COOLING WATER

COOLING WATER can be recycled or not. In case of recycling it needs to consider the evaporation and the quantity to keep low the calcium level.

Full plant (m³) Intergrade plant (m³) Pressure (°C)
Without recycling 80 per h 40 per h 25
With recycling 7 per h 3,5 per h
First fill up 420

LUBRIFICATING OIL and GREASE

LUBRICATING OIL and GREASE for gear boxes and pillow blocks for the first fill up.

  • High temperature oil: 180 kg
  • Standard oil: 180 kg
  • High temperature grease: 40 kg
  • Synthetic grease: 40 kg